Our Sungrow Inverter Troubleshooting Guide

troubleshooting Sungrow inverter

Sungrow is one of the most widely used solar inverter brands in Australia, known for being reliable and affordable – with strong local support, which is always a major plus. Your inverter’s job is to convert the DC electricity produced by your solar panels into usable AC power for your home and the grid. And most of the time, this happens seamlessly in the background – but like any technology, issues can still occur. And when it does, a little help with your Sungrow troubleshooting can go a long way!

The really good news is that, like a lot of inverters these days, Sungrow has quite superb built-in error reporting. It means that when something does go wrong, the screen or app will display an error code.

So with your code, and a little Sungrow troubleshooting assistance, you can work out whether:

  • The issue is temporary
  • It’s something you can fix yourself
  • Or it’s a sign that you need professional help.

Understanding Sungrow inverter error codes

Speak To Our Expert Electricians

We service Sydney and the surrounding areas.

Every solar inverter monitors its operating conditions – voltage, current, temperature, safety checks – and raises a Sungrow error if something is outside the safe range. Some codes point to short-term grid fluctuations that resolve on their own, while others indicate serious wiring or hardware faults that need attention.

Think of Sungrow inverter error codes as your inverter’s way of communicating. By learning to interpret them, you can quickly decide what action to take.

Grouping common error code issues

Rather than listing every single Sungrow error code (because there’s a lot!), we’ve done the hard work by grouping them into categories for you:

Issues you can usually check yourself

Voltage or frequency fluctuations: These are caused by the grid and usually self-correct (eg. code 002, 005, 008, 102).

Temporary overcurrent: A momentary surge in current that the inverter handles automatically (eg. codes 006, 007, 100, 202).

High temperature warnings: Often triggered when the inverter is working hard in hot weather (eg. codes 036, 037).

  • Check airflow
  • Shade
  • And ensure vents aren’t blocked.

Issues that need a professional

Ground faults or insulation resistance problems: These require inspection of PV strings and earth connections (eg. Sungrow error 039).

Relay or hardware faults: Internal components failing or misreading (eg. Sungrow error 038).

Persistent bus voltage problems: These happen when the inverter’s internal DC bus is outside the safe range. It’s not something you can check or fix yourself:

016 – Bus voltage/power high

019 – Transient bus voltage high

020 – Bus voltage high

200 – Bus voltage high (wait for recovery, call service if persistent)

201 – Bus voltage too low.

Arc fault warnings: Arc detection is a fire-safety feature. These faults are safety-critical and always require professional inspection by a solar repair technician.

087 – Arc self-detection anomaly warn

088 – Arc anomaly fault (disconnect inverter, check cable condition, call Sungrow if it recurs)

089 – Arc detection OFF warning.

By recognising the category, you’ll know if the inverter is simply riding out a temporary blip or whether you need expert help.

Commonly asked about error codes

Because some codes come up again and again and again, let’s tackle them directly here:

Sungrow fault 010 – This points to an islanding issue, meaning the inverter thinks it’s no longer connected to the grid. Check the AC breaker and cables, but if they look fine, call a technician.

Sungrow error 039 – Low insulation resistance. This usually means a ground fault or moisture somewhere in the PV array. A professional inspection is needed.

Sungrow error 038 – Relay fault. Sometimes this clears itself, but if the fault persists, it indicates a hardware issue that must be serviced.

Sungrow inverter error 039 – Same as above, insulation resistance problem. Never ignore it.

Sungrow error 102 – Grid frequency too low. Often just a grid supply fluctuation, but if it continues, report it to your installer or electricity provider.

Sungrow error 014 – Average grid voltage too high for more than 10 minutes. Check with your utility if it’s a supply-side issue.

Other common questions

Q: Why is my Sungrow inverter blue light flashing?
A: This light indicates the inverter is in standby or waiting mode – often due to low sunlight, grid conditions, or after a restart. If it remains flashing during full sun, it’s worth checking error messages or contacting support.

Q: What if my Sungrow app is not working?
A: If your monitoring app won’t load or display data, check your Wi-Fi connection, then restart the app. Rebooting your router can also help. If the issue persists, the inverter may have dropped its Wi-Fi link and needs to be reconnected via the monitoring portal.

How to reset Sungrow inverter?

Sometimes, the quickest fix is a simple reset. To safely reset Sungrow inverter:

  • Turn the DC isolator on the inverter to OFF.
  • Switch off the Solar Supply Main Switch (AC isolator) at your switchboard.
  • Wait one to two minutes.
  • Switch the AC isolator back ON, then the DC isolator.

This process answers the common query of how to reset Sungrow inverter – but if the same fault returns after reset, don’t keep cycling the unit. Instead, the time has come to call a professional.

When your Sungrow inverter isn’t working

Sungrow inverter not working at all? If the problem has become more than just an occasional blip, it’s best to:

  • Log the error code
  • Restart once
  • Contact your installer.

Repeated resets won’t solve deeper Sungrow inverter problems, and ignoring faults can risk efficiency loss or even safety hazards.

Why error codes are useful

It may feel overwhelming when those Sungrow inverter fault codes pop up, but they actually help narrow down the problem. Unlike some older units, the brand gives detailed Sungrow fault codes rather than a single generic warning. This means you and your installer can quickly zero in on whether it’s a grid issue, a simple maintenance task, or a serious internal fault.

They also help distinguish Sungrow errors from other solar inverter error codes, so your installer knows what to bring to the site.

Seeing ongoing Sungrow error messages?

Solar systems are long-term investments – and Sungrow inverters are designed to keep your power flowing reliably for years. When faults do crop up, those Sungrow inverter fault codes are the best clue to what’s really going on.

The golden rule is simple:

  • Minor, short-term faults often clear themselves.
  • Anything persistent or safety-related needs a licensed solar electrician.

Is your Sungrow inverter not working properly? Call the friendly team of Sydney solar electricians at Wire In Electrical for fast, professional help across Sydney.

Our top-rated Sydney electricians are ready to help you with any electrical problems with guaranteed workmanship.

Recent Posts

CONTACT US

GET A FREE QUOTE

This field is for validation purposes and should be left unchanged.